LT-WY111-A3 High-Efficiency Shower Head Comprehensive Performance Testing Machine
| 1 | Working voltage | Three-phase AC380V for water pump, heating and cooling, and single-phase AC220V for the rest |
| 2 | Power consumption | Up to 5KW |
| 3 | Working air pressure | External,0.3MPa to 0.6MPa |
| 4 | Test medium | normal temperature water to 60℃ |
| 5 | Upper computer | PLC (Computer) |
| 6 | External materials | Aluminum profile frame + aluminum-plastic sealing plate |
| 7 | Test stations | 3:1 showerhead spray Angle, 1 showerhead spray uniformity, and 1 showerhead spray force |
| 8 | Test product range | shower heads |
| 9 | Overall dimensions | Length 2600 * Width 1200 * Height 1800 (Unit: mm) |
| 1 | GB/T23447-2009 6.15 Average Spray Angle Test |
| 2 | GB/T23447-2009 6.16 Spray Uniformity Test |
| 3 | ASME A112.18.1-2018/CSA B125.1-18 5.12.3 Spray force |
| 4 | ASME A112.18.1-2018/CSA B125.1-18 5.12.4 Spray coverage |
Write your message here and send it to us