LT-WY109-A2 Hose Cold and Heat, Aging Performance Testing Machine
| 1 | Working voltage | Three-phase AC380V for water pump, heating and cooling, and single-phase AC220V for the rest |
| 2 | Power consumption | Up to 15 KW |
| 3 | Working air pressure | External,0.3MPa to 0.6MPa |
| 4 | Test station | Optional |
| 5 | Temperature | Cold water (5-20℃) Hot water (30-95℃) |
| 6 | Upper computer | Touch screen +PLC |
| 7 | Test product range | Hoses (applicable 400-2000mm) |
| 8 | External materials | Aluminum profile frame + aluminum-plastic sealing plate |
| 9 | Overall dimensions | Length 2600* Width 1000* Height 1800 (Unit: mm) |
| 1 | GB/T 23448-2009 7.9 Resistance to thermal cycling |
| 2 | GB/T 23448-2009 7.10 Aging resistance |
| 3 | ASME A112.18.6-2017/CSA B12.6-17 5.2 Intermittent impulse pressure test |
| 4 | IAPMO IGC 154-2013 5.4.1 Thermal Cycling Test for Flexible TPU Tubing |
| 5 | BS EN 1113:2015 9.4 Pressure resistance at elevated temperature |
| 6 | BS EN 1113:2015 9.5 Leaktightness after tensile strength and resistance to flexing tests |
| 7 | BS EN 1113:2015 9.6 Thermal shock test |