LT-ZY01 Inclined tower UV test chamber
| 1 | Light source | Lamp wavelength: UVA-340/UVA-313/UVA-351 (optional) Number of tubes: 8 Lamp power: 40W/Nr Lamp tube brand: domestic (teelong) Service life of lamp tube: about 1600 hours |
| 2 | Equipment functions | Basic functions: temperature, humidity, illumination, spraying and condensation Optional function: Irradiance display: equipped with handheld mounting radiation meter (optional) Illumination adjustment: dimming system |
| 3 | Technical indexes | Temperature range: RT+10 ℃ – 70 ℃ Humidity range: ≥ 75% RH Temperature uniformity: ≤ ± 3 ℃ Temperature fluctuation: ± 0.5 ℃ Blackboard temperature: 50 ℃~ 63 ℃ Distance between sample and lamp tube: 55mm Center distance in lamp tube: 65~70mm Standard test piece size: 75 * 150mm 42 pieces Irradiation intensity: 0.35-1.1W/m2 Adjustable 340mm wave band Test time: 1 ~ 9999 H, M and S adjustable |
| 4 | Safety protection system | line sequence protection, leakage protection, over-temperature protection and abnormal protection |
| 5 | Equipment service conditions | power supply: 220V; frequency: 50Hz; power: 450W |
| 6 | Environmental conditions | temperature 5 ℃~ 30 ℃ Relative humidity ≤ 85% RH |
| 7 | Liner material | SU304 stainless steel plate |
| 8 | Outer box material | SU304 stainless steel shell or A3 baked enamel |
| 9 | Control system | Teelong (touch screen and PLC controller) |
| 10 | Water source and consumption | clean water or distilled water (8L/d) (prepared by the Buyer) |
| 11 | Main components | Chint, Taiwan Mingwei |
| 12 | Irradiation sensor | intelligent irradiation sensor. Output of 0-5v signal |
| 1 | GB/T 14522-93 |
| 2 | ASTM G 154,ISO 4892-1 |
| 3 | ISO 11507 |
| 4 | ASTMD 4329 |