Chair Seating Impact and Durability Testing Machine
| 1 | Maximum Impact Height | 250mm |
| 2 | Impact Frequency | 5-15 times/minute |
| 3 |
Specimen Size Limit
|
Length 1000mm × Width 1000mm × Seat Height 300~650mm |
| 4 | Impact Weight Range | 125~500Ibs (Requires air pressure ≥0.6MPa) |
| 5 | Power Supply (Power) | 220VAC/5A, 50Hz |
| 6 | Air Source Requirements | Air pressure ≥0.6MPa; Flow rate ≥800L/min; Air source must be filtered and dried |
| 7 | Overall Machine Dimension | Approx. 1350×1000×2200mm (Length×Width×Height) |
| 8 | Machine Net Weight | Approx. 450kg |
| 9 | Control System Main Unit | Independent industrial control box with breakpoint detection and shutdown function |
product advantages
- Two Test Modes in One Bench – Switches between repeated seat impact and single one-time impact, covering durability and peak-load requirements on the same platform.
- True Free-Fall Release – An electromagnet holds and releases the impact head, so the mass falls without cylinder drag, matching the free-fall condition the standards assume.
- Unconstrained Vertical Loading – Foot-cup lateral restraints fix the chair horizontally while leaving the seat free vertically, preventing false passes from over-constrained specimens.
- 250 mm Drop, 125–500 lbs Load – The full impact weight range is adjustable, covering BIFMA X5.1 and EN 1335 impact energy levels without fixture changes.
- Power-Failure Memory – The touchscreen controller logs impact count and speed continuously and resumes the test after a power interruption, protecting long-run durability cycles.
- Low-Noise Hydraulic Buffering – A hydraulic buffer on the return stroke reduces noise and mechanical wear, keeping the bench suitable for lab and production-floor use.