LT-WY105-B Faucet Life Testing Machine
| 1 | Working voltage | Three-phase AC380V for water pump, heating and cooling, and single-phase AC220V for the rest |
| 2 | Working air pressure | External,0.3 to 0.6MPa |
| 3 | Power consumption | Up to 15KW |
| 4 | Host computer | Computer |
| 5 | Test medium | Cold water: External connection; Hot water: Room temperature water to 90℃ |
| 6 | Test Station | (Optional) |
| 7 | Test product range | 1. Single-handle dual-control water nozzle; 2. Single-handle single-control faucet 3. Double-handle double-control faucet 4. Smart faucet; |
| 8 | External materials | Aluminum profile frame + aluminum-plastic sealing plate |
| 9 | Drive unit | Servo + cylinder |
| 10 | Angle range and accuracy | Range 0 to 270°, accuracy: 0.2° |
| 11 | Flowmeter | 0-30L/min |
| 12 | Torque sensor | 0-10 N.m |
| 13 | Water pump | It can provide 0.02 to 1.0Mpa |
| 14 | Overall machine size | Depending on the number of workstations |
| 1 | GB 18145-2014 8.6.9.1 Faucet Switch Life Test | |
| 2 | GB 18145-2014 8.6.9.2 Switching Switch Life Test | |
| 3 | QB/T 1334-2013 8.10.1 Service Life of Delayed Self-closing Faucets | |
| 4 | CJ/T 194-2014 8.17.1 Faucet and Shower Life | |
| 5 |
|