| 1 | Temperature range | - 20 ℃, – 10 ℃, RT~80 ℃ |
| 2 | Humidity range | 20% – 98% |
| 3 | Temperature and humidity analysis accuracy/uniformity | ± 0.1 ℃; R.H./± 1.0 ℃; R.H |
| 4 | Temperature and humidity control accuracy/fluctuation | ± 1.0 ℃; R.H./± 0.5 ℃; R.H |
| 5 | Laboratory temperature | 35 ℃ ± 1 ℃ for saline test method (NSS ACSS)/50 ℃ ± 1 ℃ for corrosion test method (CASS) |
| 6 | Pressure drum temperature | salt water test method (NSS ACSS) 47 ℃ ± 1 ℃/corrosion resistance test method (CASS) 63 ℃ ± 1 ℃ |
| 7 | Brine temperature | 35 ℃± 1 ℃ 50 ℃± 1 ℃ |
| 8 | Brine concentration | add 0.26 grams of copper chloride (CuCl2 2H2O) per liter in 5% sodium chloride solution concentration or 5% sodium chloride solution concentration |
| 9 | Compressed air pressure | 1.00 ± 0.01kgf/cm2 |
| 10 | Spray volume | 1.0~2.0ml/80cm2/h (collect at least 16 hours and take the average value) |
| 11 | PH value | pH 6.5~7.2 3.0~3.2 |
| 12 | Spray mode | continuous spray |
| 1 | GB/T 20854-2007 Dry and wet salt spray test |
| 2 | ISO14993-2001 dry and wet salt spray test |
| 3 | GB/T 5170.8-2008 Salt spray test equipment |
| 4 | GJB 150.11A-2009 Salt spray test method |
| 5 | GB/T 2424.17-2008 Test Method for Salt Spray |
| 6 | GB/T 2423.18-2000 Alternate Salt Spray Test Method |
| 7 | GB/T 2423.4-2008 Test Method for Alternating Heat and Moisture |
| 8 | GB/T 2423.3-2006 (IEC 6008-2-78-2001) Test Method for Constant Heat and Moisture |