LT-WY38 floor drain comprehensive testing machine
| Technical parameters | ||||||
| serial number | The name of the project | requirements | ||||
| 1 | Operating voltage | Water pump, heating and refrigeration three-phase AC380V, the rest of the single-phase AC220V | ||||
| 2 | Operating air pressure | External, 0.3MPa~0.6 MPa | ||||
| 3 | Vacuum pressure | -0.085~0 MPa adjustable | ||||
| 4 | Test the product range | Floor drain | ||||
| 5 | Test medium | Room temperature water, vacuum negative pressure | ||||
| 6 | Pump flow | Under the dynamic pressure of 0.2MPa, it can provide a flow rate of not less than 60L/min | ||||
| 7 | Profile material | Aluminum profile frame + aluminum-plastic sealing plate | ||||
| 8 | Electrical power | Up to 5KW | ||||
| 9 | Test station | 2 stations, 1 performance station, 1 flow test station | ||||
| 10 | Upper computer | Computer (optional touch screen) | ||||
| 11 | The size of the whole machine | Length 2450 * Width 1100 * Height 1650 (unit: mm) | ||||
| Comply with the standards and terms | ||||||
| category | Standard name | Standard Terms | ||||
| Floor drain | GB/T 27710-2011 Floor drain | 7.5.2 Withstand voltage | ||||
| Floor drain | GB/T 27710-2011 Floor drain | 7.5.3 Containment | ||||
| Floor drain | GB/T 27710-2011 Floor drain | 7.5.4 Anti-spill performance | ||||
| Floor drain | GB/T 27710-2011 Floor drain | 7.5.5 Drainage flow | ||||
| Floor drain | GB/T 27710-2011 Floor drain | 7.5.6 Self-cleaning ability | ||||
| Floor drain | GB/T 27710-2011 Floor drain | |||||